Research & News

From Semiconductor Research to Clinical Validation

Healthrian's wearable technology began with biosignal semiconductor research and has been validated through clinical studies in emergency medicine.

Research Foundation

A Research Track Record Rooted in Semiconductor Design

Healthrian's technology originated in CEO Taehwan Roh's research on wearable biosignal semiconductors. The low-power sensor ICs, neurofeedback SoCs, and body communication technologies published at leading semiconductor conferences and journals such as ISSCC and JSSC became the foundation of today's WEDIC products and CDMO modules.

Biosignal Sensor ICs

Analog front-end and SoC designs that measure ExG signals such as ECG, EEG, and EMG at just a few µW.

Neuroengineering · BCI

A wearable neurofeedback system combining EEG monitoring with transcranial electrical stimulation (tES).

Wearable Platforms

Body area network (BAN) transceivers and patch and headband systems built on fabric-based circuit boards (P-FCB).

Clinical Validation

A randomized controlled trial of a patch-type wireless 12-lead ECG, conducted together with emergency medicine clinicians.

1,080

Google Scholar citations

ISSCC

Presented in 2011 · 2013 · 2014 · 2019

3

Clinical papers on wearable 12-lead ECG

VLSI · SoC

Key research areas, including Biomedical

Sensor Physical AI

From On-Device AI Toward On-Sensor AI

Healthrian is adding AI technology on top of its semiconductor design expertise. Aiming for Sensor Physical AI, which interprets biosignals close to the sensor where they originate, we are moving AI computation from the cloud and the device to the sensor itself.

01 · CLOUD AI

Analysis on the Server

Measured signals are sent to a server for analysis. Computing resources are ample, but this comes with communication latency and the transfer of personal data.

02 · ON-DEVICE AI

Analysis on the Device

Analysis runs inside smartphones and wearable devices. Because data never leaves the device, real-time performance and security improve.

03 · ON-SENSOR AI

Interpretation in the Sensor

Signals are interpreted directly inside the sensor IC, and only the necessary information is sent out. This direction, which reduces both power consumption and data volume, is where Healthrian is headed.

Semiconductor design × biosignal AI — Because we bring together hands-on experience designing low-power sensor ICs and ECG/EEG analysis algorithms, we are preparing for the next step: designing the sensor and the AI as one.

Semiconductors · Systems

Selected Publications

The full list is available on Google Scholar.

IEEE JSSC · 47(1):323–334, 2012

A 75 µW Real-Time Scalable Body Area Network Controller and a 25 µW ExG Sensor IC for Compact Sleep Monitoring Applications

An ultra-low-power ExG sensor IC and body area network (BAN) controller for sleep monitoring

Lee S, Yan L, Roh T, Hong S, Yoo H-J

IEEE CICC · 2012

A 46 µW Motion Artifact Reduction Bio-signal Sensor with ICA Based Adaptive DC Level Control for Sleep Monitoring System

A biosignal sensor that reduces motion artifacts using ICA-based adaptive DC control

Hong S, Lee S, Roh T, Yoo H-J

IEEE ISSCC · 2013

A 5.5 mW IEEE-802.15.6 Wireless Body-Area-Network Standard Transceiver for Multichannel Electro-Acupuncture Application

An IEEE 802.15.6 standard body area network transceiver for multichannel electrical stimulation

Lee H, Lee K, Hong S, Song K, Roh T, Bae J, Yoo H-J

IEEE ISSCC · 2014

A 2.14 mW EEG Neuro-Feedback Processor with Transcranial Electrical Stimulation for Mental-Health Management

A neurofeedback processor for mental health management combining EEG analysis with transcranial electrical stimulation (tES)

Roh T, Song K, Cho H, Shin D, et al., Yoo H-J

IEEE Trans. Biomedical Circuits and Systems · 2014

A Wearable Neuro-Feedback System With EEG-Based Mental Status Monitoring and Transcranial Electrical Stimulation

A wearable EEG monitoring and brain stimulation system based on a low-power neurofeedback SoC

Roh T, Song K, Cho H, Shin D, Yoo H-J

Clinical Research

Clinical papers published in international journals

JMIR mHealth and uHealth · 2021;9(4):e24142

Twelve-Lead Electrocardiogram Acquisition With a Patchy-Type Wireless Device in Ambulance Transport: Simulation-Based Randomized Controlled Trial

Yoon S, Kim T, Roh T, Chang H, Hwang S, Yoon H, Shin T, Sim M, Jo I, Cha W

Interactive Journal of Medical Research · 2022;11(2):e36335

Intervention in the Timeliness of Two Electrocardiography Types for Patients in the Emergency Department With Chest Pain: Randomized Controlled Trial

Yoo S, Chang H, Kim T, Yoon H, Hwang S, Shin T, Sim M, Jo I, Choi J, Cha W

Scientific Reports · 13, 4044 (2023)

Feasibility of patch-type wireless 12-lead electrocardiogram in laypersons

Yoon S, Kim T, Kang E, et al.

News

Healthrian Channels

Product news and presentation videos are available on our official channels.

YouTube

Product introductions and how-to videos

LinkedIn

Company news and careers

Facebook

Events and exhibitions

Propose a Research Collaboration

We welcome research collaboration inquiries, including clinical studies and the development of new biosignal modules.

Scroll to Top